Design of a Spray Tower for the Granulation of Melt

Authors

  • Kaiser Muslem Abd Ali Electrochemical Eng. Dept

Abstract

In this paper a simulation of cooling-solidification tower was presented, sprayed droplets is one of major methods for prilling of melt. Traditionally, this is carried out in an empty tower, and the equipment requirements for producing larger particles is very high, for analysis and simulation, mathematical model of tower, the effect of molten drop size on height of tower, heat and mass transfer coefficients are estimated according to empirical correlations. Estimations are considered based on concept of energy and mass transfer correlation equations. The results showed that the height of equipment is greatly affected by atomized particle size.

Downloads

Download data is not yet available.

Published

02-01-2015

How to Cite

[1]
K. M. Abd Ali, “Design of a Spray Tower for the Granulation of Melt”, NUCEJ, vol. 18, no. 1, pp. 111–117, Jan. 2015, Accessed: Dec. 23, 2024. [Online]. Available: https://oldjournal.eng.nahrainuniv.edu.iq/index.php/main/article/view/159