Estimation of Concentration Polarization Using the Combined Film theory/ Spiegler-Kedem Model and Empirical Correlation

Authors

  • Taha Yaseen Khalaf Biomedical Dngineering Dept./ Al-Khwarizmi Engineering College / University Of Baghdad

Keywords:

Concentration Polarization, Combined Film, Empirical Correlation

Abstract

At a given operating pressure and in a given apparatus, concentration polarization results in an increase in the effective osmotic pressure of the feed solution on the membrane surface, a consequent decrease in the effective pressure ( P ) for fluid flow across the membrane, and progressive changes in the mass transfer coefficient, product rate, and solute separation along the length of the membrane in the direction of feed flow. The problem then is to predict the

effect of concentration polarization on solute separation and on predict rate, under specified experimental condition. In the present work, the reverse osmosis

experiments were conducted in a spiral wound model to get separation data using a NaCl-water system up to 2500 ppm and cellulose acetate membrane.

The purpose of this paper is to predict and analyze the concentration polarization using a combined film theory model and empirical correlation. Therefore, the results of the experiments show that the concentration polarization affected when using different models

Downloads

Download data is not yet available.

Downloads

Published

05-03-2008

How to Cite

[1]
T. Y. Khalaf, “Estimation of Concentration Polarization Using the Combined Film theory/ Spiegler-Kedem Model and Empirical Correlation”, NUCEJ, vol. 11, no. 2, pp. 322–328, Mar. 2008, Accessed: Dec. 23, 2024. [Online]. Available: https://oldjournal.eng.nahrainuniv.edu.iq/index.php/main/article/view/527

Similar Articles

11-20 of 60

You may also start an advanced similarity search for this article.